<LOGO>
FM Transmitter Measurement Report
Created: 2026-02-28 02-26-04
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
88.50 MHz 5/5, 61 dBuV Couleur3
Pilot RDS Phase Difference
6.5 kHz 1.9 kHz -35 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 70 kHz 19219 2,3258
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,3 dBr 1,72 dBr 2,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Couleur3" 43D3 0 (No PTY) 1 0 1 1 2:25, 28.02.2026
RT
" "
AF EON
98.5, 101.4, 104.2, 104.4, 104.7, 105.6 MHz 43D1, 43D2
FM Scope Max at: 70 kHz MIN: 8 kHz % above 76 kHz: 2,3258 Acquired: 2026/02/28 2.24.59 Total samples: 19219 Equivalent time: 0:16:00 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400